National electricity grid records total collapse

naijalog by naijalog
September 29, 2017
in Top Stories
Reading Time: 1 min read
0
National electricity grid records total collapse
0
SHARES
Share on FacebookShare on TwitterShare on Whatsapp

Nigeria’s electricity grid has recorded a total system collapse, the Transmission Company of Nigeria announced on Friday.


However, it swiftly stated that restoration of the grid was at an advanced stage and explained that the total collapse was due to tripping of three generator units at Egbin power generation station.

The daily report on Nigeria’s power sector that was made available to our correspondent by the transmission company on Friday in Abuja stated that the grid collapsed totally on Thursday, September 28, 2017, after the country generated 3,515 megawatts of electricity the preceding day.

RelatedArticles

Hellen Ati Celebrates as Cubana Chief Priest Allegedly Agrees to DNA Test

Paralysed Spanish Woman Set for Euthanasia After Years of Pain and Legal Battle

The TCN said, “A total system collapse was recorded on September 28, 2017 at 20:03Hrs.

“Reports obtained from stations and the sequence of events generated by the SCADA system indicated that the system collapse was triggered by the tripping of Egbin Units ST4, ST6 and ST5 at ‘20:03:15, 20:03:32 and 20:03:34’ respectively.

“By this incident, the Nigerian electric power grid lost generation completely before restoration commenced at 20:22Hrs.”

The power transmission firm stated that a post-mortem analysis of the event indicated that grid generation was curtailed to about 4,262.7MW prior to the inception of the disturbance due to capacity under-utilisation, as the operational capability required to maintain grid stability had waned.

This, it said, left the system vulnerable to the extent that perturbations of this magnitude resulted in severe system frequency dip that culminated in system collapse.